DESCRIPTION
The MG ECU, which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if the system is malfunctioning. If any of the following DTCs are output, replace the inverter with converter assembly.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
---|---|---|---|---|---|
P0A1A-658 | Generator Control Module | MG ECU internal malfunction: Calculation check error (1 trip detection logic) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
P0A1A-791 | Generator Control Module | MG ECU internal malfunction: R/D converter communication error (1 trip detection logic) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
P1C2A-155 | Generator A/D Converter Circuit | MG ECU internal malfunction: A/D converter malfunction (1 trip detection logic) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
P1CA6-156 | Generator Control Module Malfunction | MG ECU internal malfunction: CPU ROM-RAM error (1 trip detection logic) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
P3133-659 | Communication Error from Generator to Drive Motor "A" | MG ECU internal malfunction: Communication error (from generator (MG1) to motor (MG2)) (1 trip detection logic) | Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
DTC No. | Data List |
---|---|
P0A1A-791 | Generator (MG1) Rev |
P0A1A-658 P1C2A-155 P1CA6-156 P3133-659 | - |
MONITOR DESCRIPTION
The MG ECU performs many diagnostic tests to verify proper operation of internal ECU systems. In one of these tests, the MG ECU checks the result of the generator CPU self-test. If the MG ECU detects a "Fail" from the generator CPU self-test, it will conclude that there is an internal malfunction in the generator CPU and the hybrid vehicle control ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs | P0A1A (INF 658): MG CPU ALU malfunction P0A1A (INF 791): R/D converter communication malfunction P1C2A (INF 155): A/D malfunction (1 MG CPU) P1CA6 (INF 156): RAM and ROM destruction P3133 (INF 659): MG CPU communication malfunction (1 MG CPU to 2 MG CPU) |
Required sensors/components | Inverter with converter assembly (MG ECU) |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored | TMC's intellectual property |
Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Hybrid vehicle control ECU | DTC P0A1A (INF 658/791) is not detected DTC P1C2A (INF 155) is not detected DTC P1CA6 (INF 156) is not detected DTC P3133 (INF 659) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
CAUTION / NOTICE / HINT
HINT:
PROCEDURE
1. | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT | COMPLETED |