Lexus NX: EPB High Temperature (C13AA)
DESCRIPTION
If the electric parking brake is used continuously, the parking brake actuator assembly overheat prevention stops the system.
This DTC is stored to protect the system and is not a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
| C13AA | EPB High Temperature | Both of following conditions are met: -
Electric parking brake is operating
-
Lock and release operations are performed without 2 second interval 10 times; or lock and release operations are performed without 2 second interval 5 times, and target current is not achieved during lock control
| Overheat due to continuous use of system | Yes | A message is displayed on the multi-information display indicating electric parking brake system operation is stopped due to high temperatures. |
PROCEDURE
| 1. | ELECTRIC PARKING BRAKE OVERHEAT |
(a) With the overheat warning displayed, wait for approximately 1 minute.
(b) Check if the overheat warning has disappeared.
HINT:
-
Check the display after turning the power switch off and on (IG).
-
If the display returns to normal and the electric parking brake can be operated, clear the DTC.
Chassis > Electric Parking Brake > Clear DTCs
| NEXT | | END |
READ NEXT:
DESCRIPTION The parking brake ECU assembly is supplied with power to operate the motor via the +B and +B2 terminals. DTC No. Detection Item DTC Detection Condition Trouble Area Memory Not
DESCRIPTION DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note C13AE System Information not Received Both of following conditions are met:
Power switch is
DESCRIPTION The parking brake ECU assembly communicates with the hybrid vehicle control ECU, skid control ECU (brake booster with master cylinder assembly) and deceleration sensor (airbag ECU assembly
SEE MORE:
DESCRIPTION When selecting ECO mode, the mode switch (integration control & panel assembly) operation signal is sent to the air conditioning amplifier assembly. Following this, ECO mode control is activated for the heater and air conditioning system. WIRING DIAGRAM PROCEDURE 1. READ VALUE
REPLACEMENT PROCEDURE 1. REPLACE RING PIN NOTICE: It is not necessary to remove the ring pin unless it is being replaced. (a) Remove the 12 ring pins. (b) Using a plastic-faced hammer, install 12 new ring pins. *a Upper Side *b Lower Side *c 15 mm (0.591 in.) *d 14 mm (0.551 in.)
© 2016-2026 Copyright www.lexunx.com