Lexus NX: Inspection

INSPECTION

PROCEDURE

1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

NOTICE:

  • Do not apply voltage to any terminals except terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.
  • Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly to the door.

    Click here

(a) Apply positive (+) auxiliary battery voltage to the connector terminal 2 (B).

*a

Component without harness connected

(Power Window Regulator Motor Assembly LH)

*b

Clockwise

*c

Counterclockwise

*d

Motor Gear

(b) Apply negative (-) auxiliary battery voltage to the connector terminals 1 (GND) and 7 (DOWN)/10 (UP).

(c) Check that the motor gear rotates smoothly as follows.

OK:

Measurement Condition

Specified Condition

Auxiliary battery positive (+) → 2 (B)

Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 10 (UP) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 10 (UP)

Motor gear rotates clockwise (UP)

Auxiliary battery positive (+) → 2 (B)

Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 7 (DOWN) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 7 (DOWN)

Motor gear rotates counterclockwise (DOWN)

2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

NOTICE:

  • Do not apply voltage to any terminals except terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.
  • Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly to the door.

    Click here

(a) Apply positive (+) auxiliary battery voltage to the connector terminal 2 (B).

*a

Component without harness connected

(Power Window Regulator Motor Assembly RH)

*b

Counterclockwise

*c

Clockwise

*d

Motor Gear

(b) Apply negative (-) auxiliary battery voltage to the connector terminals 1 (GND) and 7 (DOWN)/10 (UP).

(c) Check that the motor gear rotates smoothly as follows.

OK:

Measurement Condition

Specified Condition

Auxiliary battery positive (+) → 2 (B)

Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 10 (UP) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 10 (UP)

Motor gear rotates clockwise (UP)

Auxiliary battery positive (+) → 2 (B)

Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 7 (DOWN) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 7 (DOWN)

Motor gear rotates counterclockwise (DOWN)

READ NEXT:

 Installation

INSTALLATION CAUTION / NOTICE / HINT HINT: Use the same procedure for the RH and LH sides. The procedure listed below is for the LH side. A bolt without a torque specification is shown in the s

 Quarter Window Glass

 Components

COMPONENTS ILLUSTRATION *1 DECK BOARD ASSEMBLY *2 NO. 2 DECK BOARD SUB-ASSEMBLY *3 NO. 3 DECK BOARD SUB-ASSEMBLY *4 TONNEAU COVER ASSEMBLY ILLUSTRATION *1 DECK FLOOR BOX L

SEE MORE:

 Generator Control Module (P0A1A-517,P0A1A-809)

DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs indicate that a large current flowed in the inverter for the generator. The cause of this malfunction may be one of the following: Internal inverter malfunction Internal circuit malfunction in the inverter for the generator Malfunction in ECU that

 Dtc Check / Clear

DTC CHECK / CLEAR CHECK DTC (CHECK USING Techstream) (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG) and wait for 90 seconds. (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Navigation System / Trouble Codes. Body Electrical > Navigation Syst

© 2016-2026 Copyright www.lexunx.com