Lexus NX: Inspection

INSPECTION

PROCEDURE

1. INSPECT QUICK HEATER ASSEMBLY

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A-1 (B) - B-1 (E)

Always

Below 1 Ω

A-2 (E) - B-2 (B)

Always

Below 1 Ω

A-3 (B) - B-1 (E)

Always

Below 1 Ω

A-3 (B) - B-2 (B)

Always

Below 1 Ω

  • If the result is not as specified, replace the quick heater assembly.

*a

Component without harness connected

(Quick Heater Assembly)

*b

Connector A

*c

Connector B

READ NEXT:

 Installation

INSTALLATION PROCEDURE 1. INSTALL QUICK HEATER ASSEMBLY (a) Install the quick heater assembly with the screw. (b) Attach the clamp and connect the 2 connectors. 2. INSTALL NO. 1 AIR DUC

 Refrigerant

 Precaution

PRECAUTION PRECAUTIONS FOR REFRIGERANT HFO-1234yf (R1234yf) (a) Compatibility (1) The parts used in the refrigerant cycle, etc. of the HFO-1234yf (R1234yf) system are not compatible with the conventio

SEE MORE:

 Definition Of Terms

DEFINITION OF TERMS Term Definition Monitor Description Description of what the ECM monitors and how it detects malfunctions (monitoring purpose and details). Related DTCs Group of diagnostic trouble codes that are output by the ECM based on the same malfunction detection logic.

 Precaution

PRECAUTION PRECAUTION FOR REPLACEMENT (a) Always prepare a new bulb for immediate replacement. While replacing a bulb, the lens may attract dust and moisture if removed from the vehicle for a long time. (b) Always replace a bulb with another bulb of the same wattage. (c) If only replacing the bulb o