Lexus NX: Removal

REMOVAL

PROCEDURE

1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

Click here

2. REMOVE AIR CONDITIONER PRESSURE SENSOR

(a) Disconnect the connector.

(b) Using a 27 mm deep socket wrench, remove the air conditioner pressure sensor.

NOTICE:

Seal the openings of the removed parts using vinyl tape to prevent the entry of moisture and foreign matter.

*a

Turn

*b

Hold

READ NEXT:

 Installation

INSTALLATION PROCEDURE 1. INSTALL AIR CONDITIONER PRESSURE SENSOR (a) Remove the vinyl tape from the liquid pipe sub-assembly and the connecting part of the air conditioner pressure sensor. (b) Apply

 Air Conditioning System

 Precaution

PRECAUTION PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL NOTICE: After the power switch is turned off, there may be a waiting time before disconnecting the negative (-

SEE MORE:

 Customize Parameters

CUSTOMIZE PARAMETERS CUSTOMIZING WITH MULTI-DISPLAY (a) Turn the power switch on (IG). (b) Time zone setting (1) Using the multi-display, select "Setup", "General", "Clock", and then time zone and change the customize setting. Item Default Content Setting Relevant ECU Time Zone Auto

 Installation

INSTALLATION PROCEDURE 1. INSTALL AIR CONDITIONING THERMISTOR ASSEMBLY (HUMIDITY SENSOR) *1 Stopper *2 Bracket (a) Attach the 2 brackets, and carefully install the air conditioning thermistor assembly (humidity sensor) to the glass surface, preventing air bubbles from forming between