Lexus NX: Removal
REMOVAL
PROCEDURE
1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Click here
2. REMOVE AIR CONDITIONER PRESSURE SENSOR
| (a) Disconnect the connector. | |
| (b) Using a 27 mm deep socket wrench, remove the air conditioner pressure sensor. NOTICE: Seal the openings of the removed parts using vinyl tape to prevent the entry of moisture and foreign matter. | |
READ NEXT:
INSTALLATION PROCEDURE 1. INSTALL AIR CONDITIONER PRESSURE SENSOR (a) Remove the vinyl tape from the liquid pipe sub-assembly and the connecting part of the air conditioner pressure sensor. (b) Apply
PRECAUTION PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL NOTICE:
After the power switch is turned off, there may be a waiting time before disconnecting the negative (-
SEE MORE:
DTC SUMMARY MALFUNCTION DESCRIPTION This DTC indicates that an overvoltage in the inverter has occurred. The cause of this malfunction may be one of the following: Internal inverter malfunction
Inverter internal circuit malfunction
Rear traction motor with transaxle assembly malfunction
Ope
On-vehicle InspectionON-VEHICLE INSPECTION PROCEDURE 1. INSPECT ABSORBER CONTROL ACTUATOR (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: for LH Side Tester Connection Condition Specified Condition 1 (+) - 3 (-) 15 to 25°C 2.8 to 4.4