InspectionINSPECTION PROCEDURE 1. INSPECT COMBINATION SWITCH ASSEMBLY (BLIND SPOT MONITOR MAIN SWITCH) (a) Remove the combination switch assembly. Click here (b) Measure the resistance according
RemovalREMOVAL CAUTION / NOTICE / HINT NOTICE:
Avoid any impact to the blind spot monitor sensor.
Do not drop the blind spot monitor sensor. If it is dropped, replace it with a new one.
PROCE
Air outlets and fan speed are automatically adjusted according to the
temperature
setting.
Press the "MENU" button on the Remote Touch, then select
to display the
air conditioning control screen.
The air conditioning system can be displayed and operated on the side display.
Air conditi
TERMINALS OF ECU CHECK COMBINATION METER ASSEMBLY (a) Disconnect the I10 combination meter assembly connector. (b) Measure the resistance and voltage according to the value(s) in the table below. Tester Connection Wiring Color Terminal Description Condition Specified Condition I10-21