Lexus NX: On-vehicle Inspection

ON-VEHICLE INSPECTION

PROCEDURE

1. INSPECT COOLING FAN SYSTEM

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

Powertrain > Engine and ECT > Active Test

Tester Display

Control the Electric Cooling Fan

(e) Check the operation of the cooling fans while operating them using the Techstream.

OK:

Tester Operation

Fan Operation

ON

Cooling fans operate

OFF

Cooling fans stop

If the cooling fan motor does not operate, check the cooling fan circuit.

Click here

READ NEXT:

 Cooling Fan Circuit

DESCRIPTION The ECM calculates an appropriate cooling fan speed based on the engine coolant temperature, air conditioning switch condition, refrigerant pressure, hybrid coolant temperature, engine spe

 Cooling System

On-vehicle InspectionON-VEHICLE INSPECTION PROCEDURE 1. INSPECT FOR COOLANT LEAK CAUTION: To avoid the danger of being burned, do not remove the radiator reservoir cap while the engine assembly and r

 Radiator

SEE MORE:

 P/W Master Switch Communication Stop (B1206)

DESCRIPTION This DTC is stored when LIN communication between the multiplex network master switch assembly and main body ECU (multiplex network body ECU) stops for 10 seconds or more. DTC No. Detection Item DTC Detection Condition Trouble Area B1206 P/W Master Switch Communication Sto

 Terminals Of Ecu

TERMINALS OF ECU CHECK STEREO COMPONENT EQUALIZER ASSEMBLY (a) Measure the voltage and resistance according to the value(s) in the table below. Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition I117-1 (GND) - Body ground W-B - Body ground Groun