Lexus NX: Relay
On-vehicle Inspection
ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT COOLING FAN RELAY (FAN NO. 1)
(a) Measure the resistance according to the value(s) in the table below. Standard Resistance: Tester Connection | Condition | Specified Condition | 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher | Battery voltage applied to terminals 1 and 2 | Below 1 Ω | If the result is not as specified, replace the cooling fan relay. | |
READ NEXT:
ComponentsCOMPONENTS ILLUSTRATION *1 THERMOSTAT *2 WATER INLET *3 GASKET - - N*m (kgf*cm, ft.*lbf): Specified torque ● Non-reusable part RemovalREMOVAL PROCEDURE
COMPONENTS ILLUSTRATION *1 ENGINE WATER PUMP ASSEMBLY *2 FAN AND GENERATOR V BELT *3 RADIATOR RESERVE TANK ASSEMBLY *4 V-RIBBED BELT TENSIONER ASSEMBLY *5 WATER BY-PASSS HOSE
SEE MORE:
DESCRIPTION Different voltage values are sent to the multiplex tilt and telescopic ECU by operating the tilt and telescopic switch. The multiplex tilt and telescopic ECU then judges which motor and in which direction that motor should operate based on the voltage value. WIRING DIAGRAM PROCEDURE
INSTALLATION PROCEDURE 1. INSTALL BATTERY COOLING BLOWER ASSEMBLY LH CAUTION: Wear insulated gloves and use insulated tools. (a) Install the battery cooling blower assembly LH with the 3 nuts. Torque: 7.5 N·m {76 kgf·cm, 66 in·lbf} (b) Connect the wire harness clamp and connector. 2. INSTALL BAT