Lexus NX: Operation Check

OPERATION CHECK

CHECK SEAT HEATER (for Front)

(a) Turn the power switch on (IG).

(b) Check that the indicator illuminates and the surface of the front seat warms up, when the seat heater switch on the air conditioning control assembly is turned on.

(c) Check that the front seat surface temperature changes according to the operation of the seat heater switch on the air conditioning control assembly as follows: HI → MID → LO.

CHECK SEAT HEATER (for Rear) (w/ Rear Seat Heater)

(a) Turn the power switch on (IG).

(b) Check that the indicator illuminates and the surface of the rear seat warms up, when the refreshing seat switch turned on.

(c) Check that the rear seat surface temperature changes according to the operation of the seat heater switch on the air conditioning control assembly as follows: HI → MID → LO.

READ NEXT:

 Problem Symptoms Table

PROBLEM SYMPTOMS TABLE NOTICE: If the auxiliary battery voltage is low, the seat heater system may not operate. When "High Power Consumption / Partial Limit On AC/Heater Operation" is displayed on

 Terminals Of Ecu

TERMINALS OF ECU CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (a) Disconnect the I50 air conditioning amplifier assembly connector. (b) Measure the voltage and resistance according to the value(s) in th

 Diagnosis System

DIAGNOSIS SYSTEM DESCRIPTION (a) Seat heater system data and Diagnostic Trouble Codes (DTCs) can be read through the Data Link Connector 3 (DLC3) of the vehicle. When the system seems to be malfunctio

SEE MORE:

 Problem Symptoms Table

PROBLEM SYMPTOMS TABLE HINT: Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspect

 Drive Motor "A" Control Module (P0A1B-503)

DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs indicate that an overvoltage in the inverter has occurred. The cause of this malfunction may be one of the following: Internal inverter malfunction Inverter internal circuit malfunction Malfunction in ECU that controls the inverter DESCRIPTION F