Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for the specified time before touching the high voltage connectors or terminals. Then, check that the voltage is zero at the voltage inspection point on the inverter with converter assembly.
HINT:
This is the time required to discharge the high voltage capacitor in the inverter with converter assembly.
The waiting time required varies according to the model.
NOTICE:
If the auxiliary battery is fully depleted or "READY" does not light up, recharge the auxiliary battery.
Never disconnect the auxiliary battery while the power switch is on (READY).
Before giving the auxiliary battery a quick charge, disconnect the auxiliary battery cables.
Check the auxiliary battery again before the vehicle is returned to the customer.
If the auxiliary battery has been removed, clean the auxiliary battery hose and check that it is not clogged.
After installing the auxiliary battery hose, check that the hose is not kinked.
ON-VEHICLE INSPECTION PROCEDURE 1. CHECK AUXILIARY BATTERY (a) Check that the auxiliary battery cables are connected to the correct terminals. HINT: If they are not, connect them properly. (b) Check t
SYSTEM DESCRIPTION
The power steering system generates torque through the operation of the motor and the reduction gear installed on the column shaft in order to assist steering effort.
The power steering ECU assembly determines the direction and amount of assist power in accordance with vehicl
VEHICLE CONTROL HISTORY NOTICE: Make sure to record any output Vehicle Control History codes before clearing them and checking the Vehicle Control History again. CHECK VEHICLE CONTROL HISTORY (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) E